EKE-Trainnet® Temperature Sensor Input (TSI) module for acquiring and monitoring temperature sensor data.

Serial Links Interface Unit

The EKE-Trainnet® Serial Links Interface Unit (SIU) is used to implement up to eight serial links.

The physical layer level and parts of the data link layer are implemented within the SIU and higher protocol layers are implemented on the system’s Central Processing Unit (CPU). For gateway applications, the routing between the Serial Link buses and other buses is implemented by the train computer CPU module.

Shield icon representing train system compliance with industry regulations and standards
COMPLIANCE:
EN 50155, EN 45545
Looking for an EKE module?

EKE-Electronics supplies complete systems rather than individual modules. Spare parts and replacement components are available only for existing EKE systems and directly to customers operating those systems.

Key Features

Key features and benefits
Configurable Serial Links

The module has one DIN41612- F48 connector on the front panel where Serial Links can be connected. Serial links are split into two identical groups, which are isolated from the FPGA and from each other. In each group, there are four Serial Links that can be configured in different ways.

Key features and benefits
Double Buffered Serial Links

The EKE-Trainnet® SIU module provides 2 kByte long RX and TX double buffers for each serial link. The system CPU can access these buffers through the VME shared memory. A dedicated FPGA controls precise timing for all eight channels in parallel and provides convenient double buffering for the system CPU. This guarantees high performance in demanding safety critical applications.

Key features and benefits
Module & Train Computer/ System Communication

Communication between the module and the train computer/system is done through shared memory over the IEC 821 VME back plane bus.

Options

Two Versions Available

The EKE-Trainnet® SIU comes in two different versions, offering different Serial Interface combinations. Please consult the Technical Specification for the Serial Links Interface Unit.

EKE-Trainnet® Technical Specifications
Find out how we can work together