Analogue Input Module

The EKE-Trainnet® Analogue Input Module (AIM) converts the analogue signals and makes them available to the train computer’s CPU module.

The EKE-Trainnet® AIM can be used as a part of an EKE-Trainnet Train Control and Management System, Vehicle Control Unit or Event Recorder. Alternatively, the EKE-Trainnet® AIM can be fitted into the EKE-Trainnet® Remote I/O System.

The EKE-Trainnet® AIM provides a standard interface for analogue input signals. Signals can be current (-20…+20mA) and voltage (-10…10V). Separate channels are provided for frequency signal measurements with the capability to measure pulse-width ratio (PWM).

badge
COMPLIANCE:
SIL 2, EN 50126, EN 50128, EN 50129, EN 50155, EN 45545
Technical Specification for Analogue Input Module

Key Features

Current & voltage measurement channels

The current measurement channels can measure currents between -20 and +20 mA. The module has the capability to supply voltage to external sensors or to supply loop voltage to the current loops. The module’s voltage measurement channels can measure voltages between -10 and +10 V.

Over range indications for diagnostics

The resolution of the input A/D conversion is sign+12 bits, and the cut-off frequency of the hardware low pass filter is 10 Hz. Both current and voltage channels are capable of giving over range indications which can be used for diagnostic purposes.

Frequency inputs up to 16 kHz

The frequency input channels can measure frequencies up to 16 kHz, period, pulse width, pulse count and rotary decoding with direction indication (compatible with most industry standard tachometers).

32-Bit embedded processor
The module has its own 32-bit embedded processor that uses factory calibration values to convert the measurement value to mV or µA with great accuracy. The embedded processor also implements diagnostics functions and reports to the system CPU module if it suspects that the input values cannot be trusted.
SIL 2 certified

The module development is based on the railway standards EN 50126, EN 50128 and EN 50129 in accordance with safety integrity level SIL 2. A non-SIL version of the module is also available.

Options

Two options available

The EKE-Trainnet® AIM2505A has 10 current channels and 10 voltage channels divided in three isolated groups. 4 frequency channels are also available.

The EKE-Trainnet® AIM5250A has 6 current channels, and 6 voltage channels, and 4 frequency input channels in two groups: two for the low-voltage tachometer measurements and two for the high-voltage pulse width modulation measurements.

Download Brochures
EKE-Trainnet® Technical Specifications
Find out how we can work together

Technical Specification for Analogue Input Module

Dimensions (W x H x D):

4 TE x 3 U x 160 mm

Weight:

160 g

Input Power:

5 V DC ± 5 % (700 mA typ. 3 A max.)

Temperature Range (operational):

-40 °C…+70 °C

MTBF (40 ºC ambient temperature):

500 000 h (AIM2505A)
1 600 000 h (AIM5250A)

I/O Connector:

DIN41612-F48 (at front)

Host Interface:

RS 485 serial

Input Channels, Analogue:

10 voltage channels, -10…10 V (Vin) (AIM2505A)
10 current channels, -20…20 mA (Iin) (AIM2505A)
6 voltage channels, -10…10 V (Vin) (AIM5250A)
6 current channels, -20…20 mA (Iin) (AIM5250A)

Input Channels, Frequency:

4 input channels (AIM2505A)
4 input channels in 2 groups: 2 low-voltage tachometer, 2 high-voltage PWM (AIM5250A)

Frequency Input Voltage Range:

0…36 V DC

Frequency Input Threshold level:

Each channel has its own software configurable threshold level, fixed hysteresis

Frequency Input Range:

DC to 16 kHz, 0.25 Hz resolution

Frequency Input Pulse Width Measurement:

0.1% resolution

Tachometer Supply Outputs (Vout):

15 VDC, max. 100 mA