Analogue Output Module

The EKE-Trainnet® Analogue Output Module (AOM) provides a standard interface for analogue output signals..

It receives instructions from the train computer’s Central Processing Unit (CPU) module and sends analogue signals to sub-systems accordingly. The EKE-Trainnet® AOM can be used as a part of an EKE-Trainnet® Train Control and Management System, Vehicle Control Unit or Event Recorder. Alternatively, the EKE-Trainnet® AOM can be fitted into the EKE-Trainnet® Remote I/O System.

badge
COMPLIANCE:
SIL 2, EN 50126, EN 50128, EN 50129, EN 50155, EN 45545
Technical Specification for Analogue Output Module

Key Features

Four isolation groups

The module has four individually isolated analogue output groups. All groups are identical and have four analogue output channels. Each group has two PWM outputs.

Calibration and diagnostics

Each output channel has parameters for calibration (factory set), and diagnostics to detect short or open in the current loop and short in the voltage output. Outputs are factory calibrated.

Channel configuration

By default, 2 channels are configured as current loop transmitters with integrated loop supply (current mode), two channels as bipolar voltage output and two digital pulse width modulation outputs (voltage mode). The channel configurations can easily be changed from current mode to voltage mode and vice versa, depending on your needs.

32-Bit embedded processor

The module has its own 32-bit embedded processor to manage serial communication with the train computer’s CPU module. The embedded processor also implements diagnostic functions and reports to the train computer’s CPU module if it suspects that the output values cannot be trusted.

Internal current loop supply voltage

The EKE-Trainnet® AOM can provide a current loop supply voltage internally: there is no need for an external power supply. Configurable ranges are from 4 to 20 mA for current and from -10 to +10 V for voltage.

Serial bus interface

The module has an RS 485 serial bus interface for connecting to the train computer.

SIL 2 certified

The module development of AOM3371A is based on the railway standards EN 50126, EN 50128 and EN 50129 in accordance with safety integrity level SIL 2. A non-SIL version of the module, AOM2610A, is also available.

Download Brochures
EKE-Trainnet® Technical Specifications
Find out how we can work together

Technical Specification for Analogue Output Module

Dimensions (W x H x D):

4 TE x 3 U x 160 mm

Weight:

165 g

Input Power:

5 V DC ± 5 % (1 A typ., 3A max.)

Temperature Range (operational):

-40 °C…+70 °C

MTBF (40 ºC ambient temperature):

910 000 h (AOM2610A)

I/O Connector:

DIN41612-F48 (at front)

Host Interface:

RS 485

Current Output Mode:

4…20 mA
1 μA resolution

Voltage Output Mode:

-10…+10 V
1 mV resolution

Analogue Output Channels:

16 (in 4 groups of 4 isolated channels)

PWM Outputs:

8 (2 in each of the 4 groups)
Selectable base frequency 10 Hz to 10 kHz
Pulse width adjustable with 0.1% resolution
Output level 15 V